Model Number: SQC-M tank load cell
Usage: PRESSURE SENSOR
Theory: Resistance Sensor
Output: Analog SENSOR
Product name: tank load cell
Rated load: 1-3t
Rated output: 2.0±0.1%mV/V
Combined error: 0.015±% of rated output
Temperature effect on sensitivity: 0.0012±% of rated output/℃
Temperature effect on zero balance: 0.0008±% of rated output/℃
Zero balance: 1±% of rated output Ω (Ohms)
Input resistance: 385±5Ω (Ohms)
Output resistance: 351±2Ω (Ohms)
Material of elastomer: Alloy steel,stainless steel
Informations de base
Model Number: SQC-M tank load cell
Conditions de paiement et expédition
Packaging Details: Package of tank load cell:Neutral packing
Supply Ability: 8000 Piece/Pieces per Month tank load cell
Description de produit

Item/ParameterC3Unit
Rated load (Emax) 1-3 t
Maximum numbers of load cell verification Intervals3000d
Minimum numbers of load cell verification Intervals0.01% of rated load
Rated output2.0±0.1%mV/V
Combined error 0.015 ±% of rated output
Temperature effect on sensitivity 0.0012 ±% of rated output/°C
Temperature effect on zero balance 0.0008 ±% of rated output/°C
Zero balance1.0 ±% of rated output/
Input resistance 385±5 Ω (Ohms)
Output resistance 351±2 Ω (Ohms)
Insulation resistance≥5000MΩ(Mega-Ohms)
Safe overload150% of rated capability
Ultimate overload300% of rated capability
Operating temperature range-20~+70 / -20~+160C/F
Recommend excitation 8~12V(DC or AC)
Maximum excitation18V(DC or AC)
Material of elastomerAlloy steel,stainless steel
Protection classIP67/IP68